Same-day service available today·Calls answered 24/7
Call now
Home  ›  Blog

How to Tell If Your Garage Door Is Hurricane Rated

Mo Better Garage technician checking the inside of a garage door, where the manufacturer labels are

The answer to “is my garage door hurricane rated” is usually printed on the door itself. A rated door should have a label on the inside, and finding it takes a flashlight and a couple of minutes. Here’s where to look and how to read it.

01 The quick answer

To tell if your garage door is hurricane rated, go into the garage, close the door and look for the manufacturer’s label on the inside. On a rated door it gives a design pressure as two numbers in pounds per square foot (psf), one plus and one minus. Florida’s building code says what has to be on it.

“Hurricane rated” is everyday talk. The label will say wind load or design pressure. No label? Then nobody knows yet. See section 08.

Already know your door isn’t up to it? See our hurricane rated garage doors. Otherwise, grab the flashlight.

02 Where to find the label

Close the door and turn on the lights. Sweep the flashlight over the inside of each section, the bottom edge and both tracks.

Where to look for the wind load label A closed sectional garage door seen from inside the garage, with a track on each side. Numbered dots mark three places to check: the inside face of a panel, the side track and the bottom edge of the door. Door seen from inside the garage 123 123 Inside face of a panel Side track Bottom edge of the door
Three places to check first, taken from a Miami-Dade approval. Other makers vary, so sweep the whole door.

Florida’s code requires the label but doesn’t name a spot for it. Miami-Dade County approvals can. One recent approval puts the label “on the door’s side track, bottom angle, or inner surface of a panel.”

Florida’s code lets either the installer or the manufacturer mark it.

Found it? Don’t peel it off or paint over it. Take a clear photo and keep it with your house papers. You’ll want it again in section 07.

03 How to read the label, line by line

This is where your garage door wind rating lives. Florida Building Code, Residential, section R609.4.1 lists seven things the label has to identify. Here they are on a made-up label, plus the installer’s mark.

Illustration of a sample garage door wind load label An illustration, not a real product label. It shows a made-up manufacturer, a model number, a three row checklist of builds with a drawing number, plus and minus design pressures in psf and an impact rated yes or no, a Florida approval number made of zeros, and test standards. The middle row is marked as installed. Eight numbered callouts are explained in a key under the label. ILLUSTRATION. SAMPLE LABEL, NOT A REAL PRODUCT SAMPLE DOOR CO. WIND LOAD LABEL Model / Series: 0000 Installed Drawing Design pressure(psf) Impactrated DWG 101+26.0-29.0No DWG 102+36.0-40.0No DWG 103+46.0-52.0Yes Florida Product Approval: FL 00000.0 Test standards: ANSI/DASMA 108, ANSI/DASMA 115 (impact builds) Ratings apply only when installed per the drawing marked above. 12345678 12345678 Manufacturer Model or series number The marked row is the door that was installed Drawing number the door must be built to Design pressure: plus pushes in, minus pulls out Impact rated, yes or no Florida approval number (or a Miami-Dade number) Test standards the door passed
Illustration only. A sample wind load label with the lines Florida’s building code asks for. Label layouts vary by manufacturer, and many list one build instead of a checklist. The name and numbers are made up.
Line on the labelWhat it tells youWhy it matters
ManufacturerWho is responsible for the complete doorWho to ask for the drawing
Model or seriesThe door family the approval coversNeeded for any lookup
Design pressure, plus (psf)Wind pushing the door inHalf of the rating
Design pressure, minus (psf)Suction pulling the door outThe other half
Test pressure (if shown)The lab figure, commonly 1.5 times the design pressureThe design pressure is the rating
Impact ratedWhether it also passed impact testingChanges how the form in section 07 records it
Drawing numberThe installation drawing the door must matchThe rating only holds for that drawing
FL or Miami-Dade numberThe state or county approval fileThe number you look up in section 06
Test standardsWhich tests the door passedPressure only, or pressure and impact

Plus and minus. Per DASMA, the door industry’s trade association, positive pressure tries to push the door into the building and negative pressure tries to pull it out. The minus number is usually the bigger one.

The checklist. Some labels print several builds of one door, and the installer or manufacturer marks the one that went in. Only the marked row is your door.

The drawing number. Easy to skip. DASMA’s sample label says the certified values only apply when the installation follows the referenced drawings.

The test standards. If you see ANSI/DASMA 108, ASTM E330 or TAS 202, the door was pressure tested. If you also see ANSI/DASMA 115, TAS 201 and 203, or ASTM E1886 and E1996, it was impact tested too.

04 Why the label says psf and not mph

Garage doors are tested to pressures, not wind speeds, and the code requires psf on the label. A door can’t be rated to a wind speed alone.

Plus pushes in, minus pulls out Two side views of a garage door. Under Plus, arrows press on the outside of the door and it bows into the garage. Under Minus, arrows pull away from the outside and it bows outward. Plus (+) Outside Garage Wind pushes the door into the garage Minus (-) Outside Garage Suction pulls the door outward
Why the label has two numbers. Wind can push on a garage door or pull on it, and the door is tested both ways.

The same wind makes different pressure on different houses. DASMA lists what changes it: how open the land is, roof height, door size, where the door sits on the building. Waterfront gets more pressure than a sheltered street at the same wind speed. The compass direction your door faces makes no difference. So a hurricane category isn’t a door rating.

Brand codes. Clopay uses W numbers. Amarr uses WP numbers, with an “i” for impact. Its wind speed chart is footnoted for sheltered terrain and a roof under 30 feet. Wayne Dalton uses option codes. All brand shorthand, none of it required by code. One lab listing for Clopay W4 commercial doors shows six different pressure pairings under that one code. Read the psf line.

Who decides what your address needs? Your building department. DASMA calls it “the sole and final determiner” of the wind load your door needs. Ask, and they can give you the required pressures for your opening.

05 Wind rated or impact rated: two different tests

These two get lumped together. They shouldn’t be.

Wind rated (or pressure rated) means the whole door held a steady air pressure in a lab, pushed in and pulled out.

Impact rated means it also took a hit from flying debris, then cycles of pressure. In the South Florida test the “large missile” is a 9 pound 2 by 4 traveling at 50 feet per second. Yes, somebody’s job is firing lumber at garage doors.

Every impact rated garage door is wind rated. Plenty of wind rated garage doors aren’t impact rated.

Wind rated (pressure rated)Impact rated
What was testedThe door holds a steady air pressure, pushed in and pulled outThe door is struck by a 2 by 4, then cycled through pressure loads
Standards on the labelANSI/DASMA 108, ASTM E330, TAS 202ANSI/DASMA 115, TAS 201 and 203, ASTM E1886 and E1996
Where Florida code requires itAll garage doorsGlass in a garage door in a wind-borne debris region. In Miami-Dade and Broward, every exterior door, unless an approved cover protects it
On the wind mitigation formLevel D for a solid door, when verifiedLevel A or B, when verified

About that code row. A wind-borne debris region is defined two ways. It’s within a mile of the coast where the design wind speed is 130 mph or more. Or it’s anywhere the design wind speed is 140 mph or more. The rule there is written around glass. Your building department knows which side of the line you’re on. In the High Velocity Hurricane Zone (Miami-Dade and Broward counties), the rule is wider. There, every exterior door has to meet impact criteria or sit behind an approved protective cover, glass or no glass.

Lee, Collier, Charlotte, Martin and Palm Beach counties are outside that zone. A door there can still carry a Miami-Dade number, because those approvals can be used elsewhere when the local building department allows it.

06 Look up the approval number

Two kinds of number show up on Florida labels.

A Florida Product Approval number is FL plus digits, with a decimal for the specific product. Search it at floridabuilding.org, under Product Approval. Enter the number and pick a code version. The attached documents are public PDFs. They pair door widths with design pressures. See this engineer’s report and this lab listing.

A Miami-Dade Notice of Acceptance number looks like 26-0430.03. Page one of a notice gives the model, width limit, design pressure, missile impact rating, drawing and expiration date. Notices carry an expiration date and aren’t valid after it. What an expired one means for a door already in your garage is a question for your building department, or for us.

Either way, check the model, the door width and the design pressure on the record against your label and your door.

07 What the wind mitigation inspector writes down

The form is the Uniform Mitigation Verification Inspection Form, OIR-B1-1802, current revision 04/26. Question 9 covers opening protection, and it’s scored on the weakest opening in the house. A door with glass is scored with the windows. A solid door is scored with the non-glazed openings.

Form OIR-B1-1802 (Rev. 04/26), question 9. The last column assumes every window and glass door is already at Level A and the garage door is the weakest solid door on the house.
Your garage doorHow the form classifies itAnswer if all glass is Level A
Solid, impact rated, with proofLevel A, non-glazedA.1
Solid, wind pressure rated, with proof, not impact ratedLevel D, non-glazedA.2
Solid, no label or paperworkLevel X, or N if it looks impact ratedA.3
Windows, glass impact rated or covered, with proofScored with the glass, Level A or BStays A (or B, by missile size)
Windows, glass not protectedScored with the glass, Level XWhole house answer drops to X
Damaged, needs repair or replacementLevel ZAnswer Z (damaged openings). The form says a building with openings that need replacement does not qualify for wind mitigation rate differentials

The form records what is installed. Whether an answer earns a credit is the insurer’s decision.

“Verified” is the key word. The form requires at least one photo or document as proof for each item. So the right door with no label and no paperwork can go down as unverified. My Safe Florida Home explains the three answers in plain words.

The form doesn’t set a price. It says some items may not qualify for a discount, and credits depend on each insurer’s own rate file.

We don’t fill in the form. It lists who can: licensed home inspectors with the mitigation training, building code inspectors, certain licensed contractors, engineers and architects. We can identify your door and pull together its paperwork, so your inspector has something to verify.

08 No label? What that does and does not tell you

A missing sticker can mean the door was never wind rated. DASMA says not all garage doors are, and an unrated door gets no wind load label. Or the label may have come off or been painted over. Stickers have a hard life in a Florida garage. A bare door proves nothing either way.

Oddly, a label isn’t proof on its own either. Doors are assembled on site from shared parts, and DASMA tells inspectors, “Do not rely on a wind load label alone.”

Three ways to find out, easiest first:

  1. Paperwork. If the door went in under a permit, the building department’s file should hold the product approval and the design pressures. Martin County’s replacement checklist asks for exactly those.
  2. The maker or a dealer. Worth a call, with the model and any numbers on the door.
  3. A technician with the drawing. The door gets compared to an approved drawing, item by item: size, reinforcement, hinges, rollers, lock, track brackets, fasteners, glass. That’s DASMA’s inspection list, and it’s the same checking that goes into a proper garage door installation.

If the house is older and the door looks original, call the rating unknown for now. My Safe Florida Home says a wind and pressure rated door “may be likely if the home was built after 2002”. That’s a rule of thumb. If the door is showing its age in other ways too, here are the signs your garage door needs replacing.

09 What a rating does not cover

A hurricane rated garage door has a tested design pressure. No rating is a promise about a particular storm, and a few things can undo one.

Struts or a brace added later can add strength. They don’t give the door a label, an approval number or a verified line on the wind mitigation form. DASMA says owners should avoid adding reinforcement themselves, since extra weight needs matching springs and hardware. Our post on garage door hurricane brace options compares the choices.

And because we get asked every storm season: parking the car against the door doesn’t reinforce it and may damage both.

Door not rated, or no way to tell?

We install new hurricane rated doors on both Florida coasts, and the estimate on a new door is free.

Get a free estimate on a hurricane rated door

10 Hurricane rated garage door FAQ

Where is the wind load label on a garage door?

On the inside. Check the inner face of the sections, the side tracks and the bottom edge. Florida’s code doesn’t name a spot, so placement varies by maker.

What do the psf numbers on a garage door label mean?

Psf means pounds per square foot. On the label it’s the design pressure. The plus number is wind pushing the door in. The minus number is suction pulling it out. A separate test pressure, if shown, is the lab figure.

Is a garage door with no sticker hurricane rated?

Nobody can say until it’s checked. A door that was never wind rated gets no label, but labels can also come off or get painted over. The permit file, the maker or a technician with the approved drawing can answer it.

Does a garage door have to be impact rated for a wind mitigation inspection?

No. The inspection records what’s there. A verified wind pressure rated solid door goes down as Level D, and a verified impact rated one as Level A. DASMA’s reading is that the form doesn’t require a solid door outside Miami-Dade and Broward to be impact rated.

Can a brace or extra struts make my garage door hurricane rated?

No. A brace or struts can add strength, but the rating belongs to a door that was tested as built. See our post on the garage door hurricane brace.

Will a hurricane rated garage door lower my home insurance?

It can change what the inspector records on the wind mitigation form. Whether that becomes a credit, and how much, is each insurer’s decision.

Mo Better Garage, we make it WAAAY ‘mo better.

Find the label. Read the two numbers. Check for “impact rated”. Take a photo. Can’t find one, or the numbers leave you scratching your head? Any of our Florida locations can take a look.

If the answer turns out to be a new door, start with our hurricane garage doors in Florida. We’ll help with the other choices too, like insulated or non-insulated.

Contact Mo Better Garage

About Mo

Mo is the face of Mo Better Garage. Our techs have been fixing garage doors in Southwest Florida since 1991, and every guide here is written to get your door working again, cheapest fix first. Stuck? Get in touch.

Garage door acting up?

Talk to a real tech, day or night. We'll get you sorted.

Call · 24/7(239) 945-9374
  • Same-day service available
  • Calls answered 24/7
  • Upfront, itemized quotes

Need a pro instead?

Calls answered 24/7, and same-day service is available.

Skip to content